Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1128-1136, 2023.
Article in Chinese | WPRIM | ID: wpr-996867

ABSTRACT

@#Objective    To compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. Methods    Patients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. Results    A total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed peri-operative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). Conclusion    Compared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 757-764, 2021.
Article in Chinese | WPRIM | ID: wpr-886496

ABSTRACT

@#Objective    To investigate the feasibility and safety of transcatheter aortic valve replacement (TAVR) through apical approach for aortic regurgitation of large annulus. Methods    From November 2019 to May 2020, 10 male patients aged 64.50±4.20 years with aortic valve insufficiency (AI) underwent TAVR in the Department of Cardiovascular Surgery, Xijing Hospital. The surgical instruments were 29# J-valveTM modified and the patients underwent TAVR under angiography. The preoperative and postoperative cardiac function, valve regurgitation, complications and left ventricular remodeling were summarized by ultrasound and CT before and after TAVR. Results    A total of 10 valves were implanted in 10 patients. Among them, 1 patient was transferred to the aortic arch during the operation and was transferred to surgical aortic valve replacement; the other 9 patients were successfully implanted with J-valve, with 6 patients of cardiac function (NYHA) class Ⅱ, 4 patients of grade Ⅲ. And there was a significant difference between preoperation and postoperation in left ventricular ejection fraction (44.70%±8.78% vs. 39.80%±8.48%, P<0.05) or aortic regurgitation (1.75±0.72 mL vs. 16.51±8.71 mL, P<0.05). After 3 months, the patients' cardiac function was good. Conclusion    TAVR is safe and effective in the treatment of severe valvular disease with AI using J-valve.

SELECTION OF CITATIONS
SEARCH DETAIL